[pvvx_mithermometer] fix displaying negative numbers (#12735)

This commit is contained in:
hsand
2025-12-29 22:58:38 +01:00
committed by GitHub
parent 636cccc6a3
commit 2e7cdad532

View File

@@ -60,13 +60,13 @@ class PVVXDisplay : public ble_client::BLEClientNode, public PollingComponent {
* Valid values are from -99.5 to 1999.5. Smaller values are displayed as Lo, higher as Hi.
* It will printed as it fits in the screen.
*/
void print_bignum(float bignum) { this->bignum_ = bignum * 10; }
void print_bignum(float bignum) { this->bignum_ = static_cast<int16_t>(bignum * 10); }
/**
* Print the small number
*
* Valid values are from -9 to 99. Smaller values are displayed as Lo, higher as Hi.
*/
void print_smallnum(float smallnum) { this->smallnum_ = smallnum; }
void print_smallnum(float smallnum) { this->smallnum_ = static_cast<int16_t>(smallnum); }
/**
* Print a happy face
*
@@ -107,8 +107,8 @@ class PVVXDisplay : public ble_client::BLEClientNode, public PollingComponent {
bool auto_clear_enabled_{true};
uint32_t disconnect_delay_ms_ = 5000;
uint16_t validity_period_ = 300;
uint16_t bignum_ = 0;
uint16_t smallnum_ = 0;
int16_t bignum_ = 0;
int16_t smallnum_ = 0;
uint8_t cfg_ = 0;
void setcfgbit_(uint8_t bit, bool value);