Map HEAT_COOL to MODE_AUTO in HeatpumpIR component (#12058)
Co-authored-by: Copilot <175728472+Copilot@users.noreply.github.com>
This commit is contained in:
@@ -181,6 +181,11 @@ void HeatpumpIRClimate::transmit_state() {
|
||||
power_mode_cmd = POWER_ON;
|
||||
operating_mode_cmd = MODE_HEAT;
|
||||
break;
|
||||
// Map HEAT_COOL to hardware AUTO mode (automatic heat/cool changeover based on temperature).
|
||||
// In hardware AUTO mode, the device automatically switches between heating and cooling
|
||||
// based on the current temperature versus the target temperature.
|
||||
// See https://github.com/esphome/esphome/issues/11161 for further discussion.
|
||||
case climate::CLIMATE_MODE_HEAT_COOL:
|
||||
case climate::CLIMATE_MODE_AUTO:
|
||||
power_mode_cmd = POWER_ON;
|
||||
operating_mode_cmd = MODE_AUTO;
|
||||
|
||||
Reference in New Issue