# Meter Response Payload
|
||||||
|
|
||||||
|
The meter reading response contains 152 bytes of payload, most of which seems to always be zeros. The below table details the payload format.
|
||||||
|
Blank cells have never been seen to be anything other than zero. Note the table is zero-indexed
|
||||||
|
|
||||||
|
<table style="width:20%">
|
||||||
|
<tr> <td></td>
|
||||||
|
<th align="center"><img width="50" height="1">0<img width="50" height="1"></th>
|
||||||
|
<th align="center"><img width="50" height="1">1<img width="50" height="1"></th>
|
||||||
|
<th align="center"><img width="50" height="1">2<img width="50" height="1"></th>
|
||||||
|
<th align="center"><img width="50" height="1">3<img width="50" height="1"></th>
|
||||||
|
</tr>
|
||||||
|
<tr> <th>0</th> <td colspan=4></td></tr>
|
||||||
|
<tr> <th>4</th> <td colspan=4 align="center">EnergyVal</td></tr>
|
||||||
|
<tr> <th>...</th> <td colspan=4></td></tr>
|
||||||
|
<tr> <th>44</th> <td colspan=3></td><td align="center">MeterDiv</td></tr>
|
||||||
|
<tr> <th>48</th> <td colspan=2></td><td colspan=2 align="center">EnergyCostUnit</td></tr>
|
||||||
|
<tr> <th>52</th> <td colspan=2 align="center">Unknown 1</td><td colspan=2></td></tr>
|
||||||
|
<tr> <th>56</th> <td></td><td colspan=3 align="center">PowerVal</td></tr>
|
||||||
|
<tr> <th>...</th> <td colspan=4></td></tr>
|
||||||
|
<tr> <th>148</th> <td colspan=4 align="center">MeterTS</td></tr>
|
||||||
|
</table>
|
||||||
|
|
||||||
|
## Known Fields
|
||||||
|
|
||||||
|
### EnergyVal
|
||||||
|
|
||||||
|
Bytes 4 to 8, 32 bit int, unknown if signed, MSB
|
||||||
|
|
||||||
|
Energy Meter totalizer in watts, in other words, cumulative watt-hours consumed. Unknown when this value resets to zero,
|
||||||
|
might reset monthly or on start of new billing cycle.
|
||||||
|
|
||||||
|
Sometimes, an invalid number greater than `0x00400000` is returned, it is not understood when or why this happens.
|
||||||
|
|
||||||
|
### MeterDiv
|
||||||
|
|
||||||
|
At least byte 47, maybe as large as bytes 44 to 47
|
||||||
|
|
||||||
|
Some meters report values not in watts and watt hours but in a multiple of those values. `EnergyVal` and `PowerVal` should
|
||||||
|
be divided by `MeterDiv` to determine the real value. Usually this is 1, but have also seen a value of 3.
|
||||||
|
|
||||||
|
### EnergyCostUnit
|
||||||
|
|
||||||
|
Bytes 50 and 51 MSB(?)
|
||||||
|
|
||||||
|
Usually `0x03E8`, which is 1000. Theorized to be how many `EvergyVal` units per "cost unit" (a value we don't appear to have).
|
||||||
|
Since people are typically charged per kWh, this value is typically 1000.
|
||||||
|
|
||||||
|
This value is not currently used in the code
|
||||||
|
|
||||||
|
### PowerVal
|
||||||
|
|
||||||
|
Bytes 57 to 59 (24 bit signed int, MSB)
|
||||||
|
|
||||||
|
The power being consumed at the moment in Watts. If you have a grid-tie solar / wind / battery system, then this value can go negative.
|
||||||
|
Negative values are returned in 1's complement notation (if left most bit is 1, then flip all the bits then multiply by -1)
|
||||||
|
|
||||||
|
"Data Missing" / "Unknown" is denoted as max negative, `0x800000`
|
||||||
|
|
||||||
|
### MeterTS
|
||||||
|
|
||||||
|
Bytes 148 to 151 (32 bit unsigned int, LSB)
|
||||||
|
|
||||||
|
Number of milliseconds since an unknown event. Could be time since `EnergyVal` was reset, or could just be a free-running timer.
|
||||||
|
Will roll over every 49 days.
|
||||||
|
|
||||||
|
Only reported as a debugging value, not used in calculations.
|
||||||
|
|
||||||
|
### Unknown 1
|
||||||
|
|
||||||
|
Bytes 52 and 53
|
||||||
|
|
||||||
|
The meaning of the values in these fields is completely unknown. They appear to be static for each meter. Some of the observed values from users include:
|
||||||
|
```
|
||||||
|
fbfb
|
||||||
|
2c2b
|
||||||
|
3133
|
||||||
|
```
|
||||||
|
Random uneducated guess is that this is a bit field with flags about the meter configuration.
|
||||||