mirror of
https://github.com/nekorevend/esphome-emporia-vue-utility.git
synced 2026-01-10 05:10:40 -07:00
Documented the message sent when holding the reset button.
Also dug into what the "meter join" response value should be.
This commit is contained in:
@@ -11,6 +11,7 @@ Each message sent or received begins with a `$` (hex 24). Messages end with a c
|
|||||||
| m | 0x6d | Get mac address (of the MGM111)|
|
| m | 0x6d | Get mac address (of the MGM111)|
|
||||||
| i | 0x69 | Get install code |
|
| i | 0x69 | Get install code |
|
||||||
| f | 0x66 | Get firmware version |
|
| f | 0x66 | Get firmware version |
|
||||||
|
| d | 0x64 | Sent after holding the reset button for 5 seconds |
|
||||||
|
|
||||||
## Sending messages
|
## Sending messages
|
||||||
|
|
||||||
@@ -43,7 +44,7 @@ The mac address reponse bytes are in reverse order, if the device responds with
|
|||||||
The install code bytes are not swapped like the mac address payload.
|
The install code bytes are not swapped like the mac address payload.
|
||||||
|
|
||||||
#### Meter join response payload
|
#### Meter join response payload
|
||||||
This always returns a 0x01 value even if the Vue is not in range of the meter.
|
Seems to return 0x01 even if the Vue is not in range of the meter and seems to return 0x00 before ever being provisioned with the meter. At the least, `1` is good and `0` is bad.
|
||||||
|
|
||||||
#### Meter reading response payload
|
#### Meter reading response payload
|
||||||
The meter response payload has its own page [protocol-meter-reading.md](protocol-meter-reading.md)
|
The meter response payload has its own page [protocol-meter-reading.md](protocol-meter-reading.md)
|
||||||
|
|||||||
@@ -25,7 +25,7 @@
|
|||||||
// 10 to 30 seconds, so "5" is usually fine.
|
// 10 to 30 seconds, so "5" is usually fine.
|
||||||
// You might try setting this to "1" to see if your meter has
|
// You might try setting this to "1" to see if your meter has
|
||||||
// new values more often
|
// new values more often
|
||||||
#define METER_READING_INTERVAL 5
|
#define METER_READING_INTERVAL 30
|
||||||
|
|
||||||
// How often to attempt to re-join the meter when it hasn't
|
// How often to attempt to re-join the meter when it hasn't
|
||||||
// been returning readings
|
// been returning readings
|
||||||
@@ -86,7 +86,7 @@ class EmporiaVueUtility : public Component, public UARTDevice {
|
|||||||
uint16_t import_wh; // Payload Bytes 7 to 8
|
uint16_t import_wh; // Payload Bytes 7 to 8
|
||||||
byte unknown9[8]; // Payload Bytes 9 to 16
|
byte unknown9[8]; // Payload Bytes 9 to 16
|
||||||
uint16_t export_wh; // Payload Bytes 17 to 18
|
uint16_t export_wh; // Payload Bytes 17 to 18
|
||||||
byte unknown19[21]; // Payload Bytes 19 to 38
|
byte unknown19[21]; // Payload Bytes 19 to 39
|
||||||
uint32_t watts; // Payload Bytes 40 to 43 : Starts with 0x2A, only use the last 24 bits.
|
uint32_t watts; // Payload Bytes 40 to 43 : Starts with 0x2A, only use the last 24 bits.
|
||||||
} __attribute__((packed));
|
} __attribute__((packed));
|
||||||
|
|
||||||
@@ -495,6 +495,10 @@ class EmporiaVueUtility : public Component, public UARTDevice {
|
|||||||
|
|
||||||
void handle_resp_meter_join() {
|
void handle_resp_meter_join() {
|
||||||
ESP_LOGD(TAG, "Got meter join response");
|
ESP_LOGD(TAG, "Got meter join response");
|
||||||
|
// Reusing Ver struct because both have a single byte payload value.
|
||||||
|
struct Ver *ver;
|
||||||
|
ver = &input_buffer.ver;
|
||||||
|
ESP_LOGI(TAG, "Join response value: %d", ver->value);
|
||||||
}
|
}
|
||||||
|
|
||||||
int handle_resp_mac_address() {
|
int handle_resp_mac_address() {
|
||||||
|
|||||||
Reference in New Issue