Documented the message sent when holding the reset button.
Also dug into what the "meter join" response value should be.
This commit is contained in:
@@ -11,6 +11,7 @@ Each message sent or received begins with a `$` (hex 24). Messages end with a c
|
||||
| m | 0x6d | Get mac address (of the MGM111)|
|
||||
| i | 0x69 | Get install code |
|
||||
| f | 0x66 | Get firmware version |
|
||||
| d | 0x64 | Sent after holding the reset button for 5 seconds |
|
||||
|
||||
## Sending messages
|
||||
|
||||
@@ -43,7 +44,7 @@ The mac address reponse bytes are in reverse order, if the device responds with
|
||||
The install code bytes are not swapped like the mac address payload.
|
||||
|
||||
#### Meter join response payload
|
||||
This always returns a 0x01 value even if the Vue is not in range of the meter.
|
||||
Seems to return 0x01 even if the Vue is not in range of the meter and seems to return 0x00 before ever being provisioned with the meter. At the least, `1` is good and `0` is bad.
|
||||
|
||||
#### Meter reading response payload
|
||||
The meter response payload has its own page [protocol-meter-reading.md](protocol-meter-reading.md)
|
||||
|
||||